led-green Sep 7 - AppLogic 2.1 has been officially released! See the release notes for details.
Powered by AppLogic Wiki > AppLogic1 > AdvDashboardMessages Wiki webs:
Main | TWiki | Sandbox
AppLogic1 . { Changes | Index | Search | Go } Hello TWiki::User=HASH(0x 8b 4def 0)? !

Dashboard Notification Messages

Whenever important events occur on the grid, the controller posts notification messages to the grid dashboard.

These messages can be obtained in one of the following ways:

The following section describes the messages.

ALERT! Note that the message ID or text may vary slightly (e.g., number of apps failed to restart will not be listed at all if all apps restarted OK). Also, with each release of AppLogic we are improving the messages, so they will be changing in the future as well. When upgrading to a new version of AppLogic, if you use an automated system to collect and parse the notification messages, please verify that it recognizes all cases that you require.

Message ID Message text
10diskfull Controller boot volume is nearly full. Please take immediate action or contact 3tera technical support.
010_grid_boot Grid has been restarted on date. Processing reboot instructions...
010_grid_boot Grid has been restarted reason on date. Processing reboot instructions...
010_grid_boot Grid has been restarted reason on date. Restarting applications...
010_grid_boot Grid has been restarted reason on date. Application restart aborted by operator.
010_grid_boot Grid has been restarted reason on date. No applications were started because reason.
010_grid_boot Grid has been restarted reason on date. Grid restart completed on date.
010_grid_boot Grid has been restarted reason on date. Attempting application restart with m of n servers unavailable.
010_grid_boot Grid has been restarted reason on date. Application restart was aborted due to internal error; see log for details.
020_grid_start m of n applications started. x applications failed to start. y applications are not restartable. z applications are currently starting (start progress%).
020_grid_start Waiting for n more servers to rejoin the grid (timeout in t seconds)
050_metering_collect Grid metering data could not be collected due to internal error, please contact support for assistance.
050_metering_report Grid metering data could not be sent to 3tera due to internal error, please contact support for assistance.
070_vol_maint Failed to initiate volume check on date because another volume check was in progress. Please contact 3tera technical support for assistance.
070_vol_maint Volume check completed on date. Volume maintenance is required. Found x inaccessible volumes, y degraded volumes, z orphan volumes.
100_srv_server_name Lost connection to server 'server name' on date.
100_comp_server_name Server 'server name' was disabled on date because it has gone down too often within the specified time period.
300_comp_comp_name Restarted appliance 'comp_name' on date due to server failure.
300_comp_comp_name Restarted appliance 'comp_name' on date due to appliance failure.
300_comp_comp_name Failed to restart appliance 'comp_name' on date after server failure. Failed to allocate resources for appliance.
300_comp_comp_name Failed to restart appliance 'comp_name' on date after server failure. Appliance restart failed.
300_comp_comp_name Failed to restart appliance 'comp_name' on date after appliance failure.
300_comp_comp_name Restarting appliance 'comp_name' on date due to server failure.
300_comp_comp_name Restarting appliance 'comp_name' on date due to appliance failure.
300_comp_comp_name Appliance 'comp_name' restart failed at date. Appliance has failed too often within the specified time period.
300_comp_comp_name Appliance 'comp_name' failed due to server lost at date. Lost connection to server 'server name'.
500_oem_error_tnc Terms of use link is not configured. Please contact your service provider or support@3tera.NOSPAM.com
800_oem_config The OEM configuration file for this grid is missing or not readable; see log for details. Your support links and other provider-specific information displayed on the dashboard may be incorrect, as the OEM configuration has not been applied. This error does not affect the operation of your grid. Please contact your service provider for assistance.