Dashboard Notification Messages

Whenever important events occur on the grid, the controller posts notification messages to the grid dashboard.

These messages can be obtained in one of the following ways:

  • looking at the grid dashboard with a browser
  • retrieve the messages from the shell using the message list command (it is possible to obtain that list programmatically via ssh)
  • receive notifications in e-mail messages

The following section describes the messages.

ALERT! Note that the message ID or text may vary slightly (e.g., number of apps failed to restart will not be listed at all if all apps restarted OK). Also, with each release of AppLogic we are improving the messages, so they will be changing in the future as well. When upgrading to a new version of AppLogic, if you use an automated system to collect and parse the notification messages, please verify that it recognizes all cases that you require.

Message ID Message text
10diskfull Controller boot volume is nearly full. Please take immediate action or contact 3tera technical support.
010_grid_boot Grid has been restarted on date. Processing reboot instructions...
010_grid_boot Grid has been restarted reason on date. Processing reboot instructions...
010_grid_boot Grid has been restarted reason on date. Restarting applications...
010_grid_boot Grid has been restarted reason on date. Application restart aborted by operator.
010_grid_boot Grid has been restarted reason on date. No applications were started because reason.
010_grid_boot Grid has been restarted reason on date. Grid restart completed on date.
010_grid_boot Grid has been restarted reason on date. Attempting application restart with m of n servers unavailable.
010_grid_boot Grid has been restarted reason on date. Application restart was aborted due to internal error; see log for details.
020_grid_start m of n applications started. x applications failed to start. y applications are not restartable. z applications are currently starting (start progress%).
020_grid_start Waiting for n more servers to rejoin the grid (timeout in t seconds)
050_metering_collect Grid metering data could not be collected due to internal error, please contact support for assistance.
050_metering_report Grid metering data could not be sent to 3tera due to internal error, please contact support for assistance.
050_filer_status
060_ha_check HA check completed on date; the following problem(s) were found that may result in application downtime in the event of a server failure:
m running applications have degraded volumes [list].
There are not enough available resources to restart components running on n server(s) [list].
o catalog class(es) with shared volumes have degraded volumes [list].
060_ha_check HA check completed on date: HA is unavailable due to the grid being a single server grid.
060_ha_check HA check completed on date: HA is unavailable due to the grid having no enabled servers.
060_monitoring_email_nfy Dashboard message change email notification could not be sent due to internal error - see log for details. Please contact technical support for assistance.
060_monitoring_email_nfy Dashboard message change email notification could not be sent due to missing applogic configuration. Please contact technical support for assistance.
060_monitoring_email_nfy Dashboard message change email notification could not be sent due to invalid severity specified within applogic configuration file. Please contact technical support for assistance.
060_monitoring_email_nfy Dashboard message change email notification could not be sent due to SMTP error. Please contact technical support for assistance. Internal condition 'filer status' occurred. This condition should not affect the operation of your grid. Please notify 3Tera support that this error has occurred and reference SCR2301.
060_monitoring_email_post Summary email notification could not be sent due to internal error - see log for details. Please contact technical support for assistance.
060_monitoring_email_post Summary email notification could not be sent due to SMTP error. Please contact technical support for assistance.
070_vol_maint Failed to initiate volume check on date because another volume check was in progress. Please contact 3tera technical support for assistance.
070_vol_maint Volume check completed on date. Volume maintenance is required. Found x inaccessible volumes, y degraded volumes, z orphan volumes.
100_srv_server_name Lost connection to server 'server name' on date.
100_comp_server_name Server 'server name' was disabled on date because it has gone down too often within the specified time period.
200_app_app_name Backup of application app_name successfully completed
200_app_app_name Restore of application app_name successfully completed.
200_appA_app_name Backup failed to delete files from _impex volume.
200_appA_app_name Restore failed to delete files from _impex volume.
200_appB_app_name Prune of old app_name backups failed.
200_appSLAA_app_name app_name: SLA counter collection from MON failed - policy not enforced
200_appSLAB_app_name app_name: SLA cronjob cannot re-start the daemon - policy not enforced
200_appSLAC_app_name app_name: SLA - all appliances are running in the appliance group appliance_group but start condition is true
200_appSLAD_app_name app_name: SLA failed to start appliance appliance_name - marking as ignored
200_appSLAE_app_name app_name: SLA failed to stop appliance appliance_name - marking as ignored
200_appSLAF_app_name app_name: SLA - no appliances are running in the appliance group appliance_group
200_appSLAG_app_name app_name: SLA policy does not match appliance group. Please re-define the policy. Until then, policy enforcement cannot occur.
300_comp_comp_name Restarted appliance 'comp_name' on date due to server failure.
300_comp_comp_name Restarted appliance 'comp_name' on date due to appliance failure.
300_comp_comp_name Failed to restart appliance 'comp_name' on date after server failure. Failed to allocate resources for appliance.
300_comp_comp_name Failed to restart appliance 'comp_name' on date after server failure. Appliance restart failed.
300_comp_comp_name Failed to restart appliance 'comp_name' on date after appliance failure.
300_comp_comp_name Restarting appliance 'comp_name' on date due to server failure.
300_comp_comp_name Restarting appliance 'comp_name' on date due to appliance failure.
300_comp_comp_name Appliance 'comp_name' restart failed at date. Appliance has failed too often within the specified time period.
300_comp_comp_name Appliance 'comp_name' failed due to server lost at date. Lost connection to server 'server name'.
400_alert_comp_name Counter 'counter_name' in component 'comp_name' was out of range on date. Counter value is counter_value.
400_alert_comp_name Multiple alarms have occured for component comp_name. Last alarm was: Counter 'counter_name' was out of range on date. Counter value is counter_value.
400_alert_comp_name Alert from component 'comp_name' on date: msg
400_alert_comp_name Multiple alarms have occured for component comp_name. Last alarm occured on date: msg
500_oem_error_tnc Terms of use link is not configured. Please contact your service provider or support@3tera.NOSPAM.com
800_oem_config The OEM configuration file for this grid is missing or not readable; see log for details. Your support links and other provider-specific information displayed on the dashboard may be incorrect, as the OEM configuration has not been applied. This error does not affect the operation of your grid. Please contact your service provider for assistance.